Why These Seven Criteria Come First
An LPG tanker purchase usually starts with "how many cubic metres do I need" and ends with price. What really decides the life of the vehicle, its fuel cost and the frequency of problems is not capacity but the regulatory class of the cargo, the detail of the coating and the axle load. Two LPG tankers of equal capacity on the same chassis can differ considerably in annual operating cost, so keep these seven headings next to the price line.
1. ADR Class and UN Number
The UN number of the cargo is the first input into tank design and cannot be changed after assembly. Crude LPG is carried as UN 1075, propane as UN 1078, n-butane as UN 1011 and a propane–butane mixture as UN 1950. Plate thickness, weld joint design, the discharge arrangement and even the type of extinguisher required on board are all calculated from that three-digit number.
A wrong number stops the vehicle
- UN 1075 — liquefied petroleum gas; widely used in distribution and industrial plant transport
- UN 1950 — propane/butane mixture; common at autogas and cylinder filling centres
- UN 1219 — alcohol groups with not more than 60 per cent alcohol; ADR class 3, and it does not share the LPG equipment set
One question is enough at the purchasing stage: is the product name and the UN number on the data plate consistent, and is that number exactly the UN number of the cargo you will carry? An inconsistency shows up at the first checkpoint, not at the inspection office.
2. Manhole Diameter and Access (≥500 mm)
The manhole is the most used point on an LPG tanker: cleaning, level measurement and sampling all happen through it. Its diameter is set by the working space the equipment needs, not by looks. The standard is a clamped, gasketed manhole of 500 – 600 mm; narrow bodies may need 700 mm.
A small manhole means a long wait
- With a small diameter the operator loses working space for tools, hose and sample containers
- A mixer or lifting device mounted over the opening is harder to fit and remove on a narrow cover
- The ladder and handrail must not stand in front of the manhole; access has to come from the side
The practical rule is simple: measure the widest internal clearance your pump, mixer and sample container need, then select a manhole at least 100 mm larger than that.
3. Leak Detection and the Safety Valve (PSV)
An LPG tanker is also a pressure vessel, so leak control does not stop at a wetness reading. Correct equipment places a PSV (safety relief valve), a valve/vent valve, a relief valve that discharges excess pressure, and optionally a rollover protection valve on the upper dome.
Four questions to ask at commissioning
- Are the set pressure and capacity of the PSV in line with the design values ADR defines for the relevant pressure group?
- Can the leak detection valve monitor liquid and vapour separately, and is its alarm output wired to the vehicle panel?
- Is the pressure gauge delivered with its calibration date?
- Does the rollover protection close the relief path on overturning so that no liquid enters the body?
One general rule: leak detection on an LPG tanker is not a one-off tightness test; it is continuous monitoring, the PSV and the alarm chain installed together. Without all three, the tank stays in a loaded yard until the leak is noticed.
4. Axle Load and the KMR Calculation
Capacity cannot be chosen independently of axle load. Body and cargo weight are distributed over the legal axle limits and the axle arrangement, and the KMR calculation shows overload risk on the route in advance. At an LPG density of about 0.51 t/m³, a 40 m³ tank carries roughly 20 t when full.
Have the calculation done before ordering
- Total mass and maximum permissible load per axle must be read from the chassis specification
- The centre of gravity of the body has to be positioned so that axle loads are balanced when full
- A load gathered on a single axle causes trouble at bridges and narrow passages; the calculation reveals this before assembly
5. Coating: Chromate Conversion + Epoxy + 2K Polyurethane
Steel or stainless body, the external protection still has three layers: zinc chromate conversion coating, an epoxy intermediate coat and a 2K polyurethane topcoat. Chromate conversion forms a barrier on the steel surface and delays the point where corrosion starts.
What must be measured in the coating
- Surface preparation must reach Sa 2½ by abrasive blasting: a surface free of dust, oil and rust
- Conductivity (soluble salts) test results must be written into the file
- Dry film thickness (DFT) must be measured, and any surface outside the target range must be reworked
6. Capacity versus Practical Output
With LPG there is always a difference between nominal capacity and what can be filled in one go: space is left for the liquid to expand as it warms, and the filling ratio stays below the ADR limit. A tank marked "24 m³" therefore means 22 – 23 m³ under working conditions.
Increasing the volume does not always pay
- A larger volume means more product per trip, but it also extends the waiting time at the filling station and the time spent at the manhole
- As volume grows, kerb weight and axle load rise, and that directly determines the chassis choice
- For short-distance distribution a medium volume works better; for long haul a higher volume is more comfortable
7. Manufacturer Reference and Field Service
LPG tankers go through periodic inspection because of ADR requirements, and over the tank's life the gaskets, valve bodies and manhole covers are replaced several times. Whether the manufacturer can supply those items, has field service and keeps an open spare parts list should therefore be asked at the first quotation stage.
Always request these with the quotation
- A spare parts list and prices for the manhole, PSV, valves and gaskets
- The assembly drawing and layout dimensions for the given chassis brand
- A commitment that the production records, WPS/PQR documents and inspection file will be handed over on delivery
Decision table
| Criterion | Question to ask | Correct answer |
|---|---|---|
| UN number | Does the plate number match the product? | Exactly the number of the cargo |
| Manhole | Does your equipment pass through it? | 500 – 600 mm, side access |
| PSV and detection | Are PSV, detection and alarm fitted together? | All three, wired to the panel |
| Axle load | Are the axles within limits when full? | Confirmed by the KMR calculation |
| Coating | Is the DFT measurement recorded? | Sa 2½ and measured film thickness |
| Capacity | Nominal or fillable? | Filling ratio within the ADR limit |
| Service | Are spare parts and field support available? | List and team available |